Add to Favorites
Tengcon HOT | Set as homepage | Add to Favourites | Contact Us
  Base Information
Name:T-903S Ethernet I/O(16AI)
Data download:Click Here
  Product introduction

16 channel analog input (0~5v or 0~20mA) , 16 bit AD  

1 port  10M/100M Ethernet, MODBUS TCP / ENET  IEC870-5-104

Two  RS485 or RS232 ports , MOBUS RTU , 300-38400bps 

AC(85-265V)  or DC 24V  power supplies

Model Number

 TENGCON T-903S (16AI)

Physical Feature

Dimension

169 x 134 x 63 mm (W x H x D)

Weight

0.5 Kg

Mount

Standard rail or bolts

Working Temperature

From -40ºC to 85 ºC

I/O Feature

Built-in analog inputs

16 (0-20mA or 0-5V)

I/O state indicators

44 pcs.

Output image

256 Byte (192 Byte for analog inputs )

Power Supply and power output

Power Supply

Rated Voltage

220V AC or 24V DC

 

Range

From 90V AC to 250V AC, 50Hz, or 24V DC

 

Rated current

40mA/220VAC(24V DC output in full-load) 

20mA/220VAC(24V DC output in no-load)

14mA/220VAC(24VDC output in full-load)

Isolated power output

Rated voltage

24VDC

 

Rated current

0.2A

 

Output resistance

About 20 Ohm

 

Terminals

VOUT(24V+24V-)

Analog input

Input signal

0-20mA in current input / 0-5V in voltage input

Input configuration

Software configurable to current or voltage input

1 : voltage   0:current     (default:1)

Inputs

16

Terminals

(AI0.0~0.7,M; AI1.0~1.7,1M

Input resistance

About 258Ω

About 200KΩ

Indicators

The LED indicator,

voltage input:

voltage <0.25V,LED indicator off

0.75V<voltage<5V,LED indicator on

Voltage>5V or 0.75V<voltage<5V , LED indicator flash

current input:

3mA<current <20mA,LED indicator on

current>20mA or current<3mA,LED indicator flash

Resolution

16-bit

Digital scope

0-20000

Conversion cycle

10ms

Communication 

Ethernet

1 port  (RJ45, 10M/100M adaptive,MODBUS TCP protocol)

RS232

1 port  (COM0, for internal test)

RS232/485

2 port 

COM2, DB9 RS232 direct connect

COM1, DB9 RS485(pin 2 is B, pin 3 is A)

Default settings: MODBUS RTU Slave, Bode rate 19200,1,8,E, address 1

CAN

1 port

DIP

8-bits 

Set DIP ON will force the IP address to the default

192.168.1.99

Run/stop switch

2 switches 

run/stop(in stop mode, only PLC program stopped)

Communication indicator

6 pcs. 

Memory

User program memory size

2M Byte

User data memory size

2M Byte

Back-up battery data memory

1K Byte

Data back-up time

1 year

CPU feature

CPU frequency

48 MHz

Max. 72 MHz

Minimum instruction processing time

4 millisecond

 

INT and Bit operation

From 1 to 4 microsecond

 

Floating-point algorithm

About 40 microsecond

 

1ms timer quantity 

No limit

 

Clock

Internal clock

Back-up battery

Copyright(C)2011 Beijing Tengcon Technology Co.,Ltd. TEL:010-59790086